An Arduino-based vane-anemometer and differential-pressure rig that maps airflow through a modelled mine ventilation network
Mapped to your syllabusVTU 2022 Scheme (OBE/CBCS) · BXX685 Major Project Phase-I · Semester 6Low-Cost Mine Ventilation Airflow Survey Instrument and Gallery Network Study builds a compact, Arduino-based airflow measuring kit and then uses it the way a ventilation officer uses a full-size anemometer set: to run a traverse survey of a ventilation network, station by station, and turn the readings into air quantities, pressure drops and branch resistances.
Underground mines in India — the coal mines of Jharkhand and Telangana, the iron-ore mines of Ballari and Goa — depend on mechanical ventilation networks whose performance is checked by periodic airflow surveys. Commercial survey instruments (digital vane anemometers, manometers and smoke tubes) cost tens of thousands of rupees, so most college mining labs cannot give every batch hands-on practice. Our rig changes that: a pulse-output vane anemometer measures air velocity, an MPXV7002DP differential-pressure sensor reads the static-pressure difference across doors and regulators on a scale model, and an Arduino Uno time-stamps and logs every reading to a microSD card.
The survey target is a modelled gallery network — a plywood-and-acrylic single-entry system with a parallel split, an air door and a regulator, driven by a 12 V duct fan. The team calibrates the sensors against a reference anemometer and an inclined manometer, runs repeat traverses, computes air quantity (Q = v × A) and branch resistance (R = Δp/Q²) in Python, and checks how the model compares with a hand-worked Atkinson-equation calculation. The firmware is central to the build, so the source bundle includes the complete Arduino sketch and the Python reduction scripts.
Syllabus alignment
Airflow surveys are the foundation of mine ventilation management, yet mining-engineering students in most Indian colleges practise them only as solved numerical problems. A survey-grade digital anemometer kit costs ₹40,000 or more, so departments cannot stock one per batch, and hands-on training is limited to a single demonstration unit. As a result, graduates join mines having never planned stations, held an instrument steady for a timed interval, or reconciled measured readings against a ventilation network calculation.
There is a need for a low-cost, loggable airflow survey instrument and a modelled gallery network on which a student team can run the complete survey workflow — station selection, velocity and pressure measurement, repeat readings, data reduction to quantity and resistance, and comparison with predicted values — at a total cost under ₹12,000, with firmware and data handling the students write and defend themselves.
This project designs, calibrates and demonstrates a low-cost airflow survey instrument for mine ventilation teaching, built around an Arduino Uno, a pulse-output vane anemometer and an MPXV7002DP differential-pressure sensor. The instrument is validated in the laboratory and then used to conduct a formal airflow survey of a modelled mine gallery network, producing air quantities, pressure drops and resistances for each branch.
Every underground mine is a network of connected airways whose behaviour is governed by pressure and resistance. The ventilation officer's basic tool is the airflow survey: measuring velocity and cross-sectional area at fixed stations, computing air quantity, and measuring the pressure differential across branches to derive their resistances. Comparing two surveys months apart reveals leaking doors, blocked airways or failing fans long before conditions become dangerous. Students usually see this only on the blackboard, because one survey-grade instrument set costs more than a department's annual lab budget.
In scope
Out of scope
The project follows a build → calibrate → survey → reconcile sequence organised as a two-phase VTU major project (Phase-I in Semester 6, Phase-II in Semester 7).
| Phase | Weeks | Work | Deliverable |
|---|---|---|---|
| Literature & definition (Phase-I) | 1–2 | Study DGMS technical circulars, CMR 2017 ventilation requirements and survey texts; finalise problem statement and specifications | Phase-I report (BXX685) |
| Circuit & firmware | 3–4 | Wire the Uno, anemometer pulse input (interrupt), MPXV7002DP to A0, DS3231 RTC and SD module; write and unit-test the C sketch | Working logger |
| Calibration | 5–6 | Velocity: 8-point fit vs reference anemometer; pressure: 5-point fit vs inclined manometer; repeatability runs | Calibration report with error bands |
| Model gallery | 7–8 | Fabricate the plywood/acrylic network, mount the fan, door and regulator, seal joints with silicone | Completed model |
| Survey campaign | 9–10 | Mark stations, run 3 repeat traverses per configuration (door open/closed × regulator positions) using the survey sheets | Raw CSV logs + survey sheets |
| Data reduction & reconciliation | 11–12 | Python scripts compute Q, Δp, R per branch; plot measured vs calculated; analyse deviations (friction factor, leakage) | Results chapter |
| Documentation & viva | 13–14 | Phase-II report (BXX786), PPT, dry-run demonstration | Final submission |
Testing approach: instrument-level checks (zero-offset, span, repeatability), survey-level checks (mass balance — inlet quantity should equal the sum of branch quantities within a stated tolerance), and end-to-end verification of the CSV log against manual stopwatch readings. Every error source (sensor resolution, area measurement, averaging time) is listed with its estimated contribution.
The instrument follows a simple sensor → microcontroller → storage pipeline, and the study follows a measure → reduce → reconcile pipeline; the two meet in the CSV log.
flowchart TD
AN["Vane anemometer (pulse output)"] -->|interrupt pulses| U["Arduino Uno logger"]
PS["MPXV7002DP across door/regulator"] -->|0.5-4.5 V on A0| U
RT["DS3231 RTC"] -->|timestamp via I2C| U
U -->|CSV row| SD[("microSD card")]
U -->|live values| LCD["16x2 LCD"]
SD -->|copied after survey| PY["Python reduction scripts"]
PY --> Q["Air quantity Q = v x A per station"]
PY --> R["Branch resistance R = dp / Q^2"]
Q --> RC{"Reconcile vs Atkinson calculation"}
R --> RC
RC --> REP["Results chapter + survey sheets"]The reconciliation step closes the loop: where measured and calculated resistances disagree by more than the stated tolerance, the team re-examines joint leakage, area estimates and averaging time before accepting the value — exactly the judgement a survey report demands.
Module 01
Owns the two sensing channels: mounting the vane anemometer and MPXV7002DP with the correct tubing and orientation, and running the calibration campaign against the reference anemometer and inclined manometer. Delivers the calibration fits, repeatability statistics and the uncertainty table that every later result inherits.
Module 02
Writes the Arduino C sketch: interrupt-based pulse counting over a timed gate, analog sampling with 50-sample averaging for the pressure channel, DS3231 timestamping, SD-file creation with header row, LCD live readout and push-button control of gate length. Delivers the tested .ino source included in the source bundle.
Module 03
Designs and builds the modelled gallery network — airway sections, air door, adjustable regulator and fan mounting — and plans the survey: station numbering, cross-section measurement grid, traverse order and the DGMS-style survey sheets used to record each run.
Module 04
Develops the Python scripts that parse the CSV logs, apply calibration coefficients, compute per-station quantity and per-branch resistance, fit the measured-vs-calculated comparison and produce the plots. Also performs the mass-balance check that validates each traverse before it enters the report.
Slide 1
Low-Cost Mine Ventilation Airflow Survey Instrument
Slide 2
Why Ventilation Surveys Matter
Slide 3
Problem Statement
Slide 4
Objectives
Slide 5
Instrument Design
Slide 6
Calibration Protocol
Slide 7
Modelled Gallery Network
Slide 8
Survey Procedure
Slide 9
Data Reduction & Results
Slide 10
Limitations & Individual Contribution
Slide 11
Conclusion & Future Scope
Bullets, speaker notes and the .pptx · ₹2,000
Read each answer, close it, and say it in your own words. Your viva will ask. Now you'll know.
A survey establishes the air quantity flowing in each airway, the pressure drops across branches and regulators, and hence the resistance distribution of the network. It is periodic because conditions change — doors wear, airways collapse or get over-excavated, and fan performance drifts — so comparing successive surveys catches these changes before they become hazardous or wasteful.
A vane anemometer's pulse output is a digital count that the Arduino can measure with interrupts, giving clean timing and no analog drift, and the sensing element is robust to dust and handling. A hot-wire sensor is sensitive at very low velocities but is fragile, direction-sensitive and needs careful temperature compensation — none of which suits a student-built survey kit.
It measures differential static pressure between its two ports, which on our model is the drop across the air door or regulator. Door and regulator differentials in the model are tens to a few hundred pascals, comfortably inside ±2 kPa, while the analog output spans 0.5–4.5 V so the Uno's 10-bit ADC gives usable resolution across that working range.
+11 more questions, with answers
Unlocks with the project · ₹2,000
Unlock for ₹2,000What to change before it goes anywhere near a submission. Skipping it is how the demo fails live.
Unlocks with the project · ₹2,000
Unlock for ₹2,000How to study it, adapt it and walk your examiner through it, step by step.
Unlocks with the project · ₹2,000
Unlock for ₹2,000OnlyProjects. (2026). Low-Cost Mine Ventilation Airflow Survey Instrument and Gallery Network Study: B.Tech / B.E. Mining Engineering project bundle [Educational resource]. https://onlyprojects.online/projects/btech-mining-ventilation-airflow-survey-instrument-study
Keep browsing
Same degree, same syllabus slot, different idea. Pick the one your guide will actually approve.
Cyber Security
Flows, top talkers and scan indicators for the lab's own network — headers only, no blocking, full history
Mechanical Engineering
A human-powered spiked-roller dehusker for small coconut growers around Pollachi — designed, fabricated and tested for ₹ under 20,000
Aerospace / Aeronautical
Build a subsonic test tunnel on a student budget, then trace lift and drag on a 3D-printed NACA 0012 against theory
Agricultural Engineering
Irrigates vegetable beds by soil-moisture thresholds instead of habit, and proves every litre with a flow meter
Artificial Intelligence & Machine Learning
Forecasts kharif yield for Karnataka districts from six decades of ICRISAT district data and tells extension officers which crops look safe this season
Artificial Intelligence & Machine Learning
Screens CPCB river-water samples into quality bands, flags stations that fail bathing criteria and predicts likely BOD exceedance when lab results are missing